What is Solar UPS?
Inverter

High Energy
Storage
(sufficient for homes)
Slow switchingUPS

Low Energy
Storage
(sufficient for Pcs)
Fast switchingSolar Inverter

High Energy Storage
(Battery charging from Grid or Solar power)
No preference for Solar PowerSolar UPS
the best of all options
The Solar Home UPS has capability to charge batteries from Solar Source,
Grid Power or DG power source, possesses high energy capacity & has
intelligence to give priority to Solar Power. It uses Grid Power
only when Solar Power is insufficient to meet load requirements..
Now that's Truly Brainy
What does a Solar UPS do?
During power-supply
Stablizes Power Supply to keep
your
appliances healthy and
Charges batteries
on Preferred
Solar Mode
During power-cut
Smartly switches to battery
power
and provides a regulated
power supply
for your home.


a Home UPS. With a brain.
Powered with Artificial Intelligence.
works in four modes

Solar
Mode
Intelligent solar charge controller

The inbuilt Solar Charge Controller manages power for you. It regulates the voltage and current from your Solar Roof to optimally charge the batteries when it's sunny outside, and shifts to Grid Supply when solar power is unavailable.
Prioritized
Charging
Keeping Solar as the first choice
Brainy Plus is designed to give priority to Solar over Grid/ DG power while charging battery. For example if battery needs 15 Amp and Solar is giving 12 A then it will take only 3A from Grid for charging battery.
When Solar Power is sufficient: Charges the batteries through solar power
When solar power is insufficient:
Charges batteries by drawing the
remaining power from the Grid supply.

Beast
Battery
Longevity reimagined.
Brainy Plus is designed to give priority to Solar Charging or Grid Charging. Charging batteries through solar mode can give a whopping 98% charging efficiency which enhances the battery's life by 6 months.

Power
Plus
Powerful 30 Ampere Solar Charger
Brainy Plus has a built-in, powerful and intelligent Solar Charger that can run the load and charge batteries simultaneously. This is multitasking at its best in an inverter.

Smart
Control
4th Generation Microprocessor,
wired in.

Adaptive
Performance
Automatic Temperature Compensation (ATC)
Brainy Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Brainy Plus senses the temperature around it and then makes intelligent adjustments.

Adaptive
Performance
For example, in summers or hotter regions, the temperature is high,
and hence the battery is charged to a lower voltage for the same power
back-up performance. This saves you some extra bucks while also
making sure the battery doesn't overheat, lose water, or get damaged.
Similarly, in winters or colder places, the temperature is lower and hence
the battery is charged to a higher boost voltage to make sure you get
the required or expected amount of power back-up.
This makes Brainy Plus a perfect choice for any climate, from the extremes
of Northern America and Europe to the beating heat in Middle-East and
South-East Asia, we are ready for a rough world.

Safe
Charging
Six Stage Charging
Most inverters charge the battery in a flat, linear manner. But just like
monotony upsets you, monotonous or flat charging deteriorates battery
health.
Ideally, 80% of a battery should be fast-charged, while the rest 20% should
be charged slowly to avoid over-heating and loss of water-topping. With
its Generation Four microprocessor, Brainy Plus carries out charging
in six thoughtful stages for maximum efficiency in charging.

Inverter
Mode
Charging and backup cycles.
The battery sits at the heart of your inverter's power back-up
functionality. Charging and Dis-charging cycles define life of a
battery, and making both these processes efficient is crucial.
Brainy Plus is built to keep your battery healthy. It is designed
for efficient charging and discharging, hence keeping the battery
running for longer with reduced upkeep efforts and costs.

Choice of battery: depends upon Load & Back up time
Example 1-2 BHK, 250W loadLow back-up (15 min)
Sealed Maintenance Free60Ah
Medium back-up (1 Hr)
Tubular/LA75Ah to 100Ah
High back-up (3 - 4 Hr)
Tubular/LA150Ah
Battery Charging Mechanism:
Brainy Plus is built with a Right Charging Mechanism that
charges batteries optimally for longer life

Pure
Wave
Pure Sine Wave Technology
Many inverters still provide a square wave output which is not healthy for your appliances. Brainy Plus is designed to provide a smooth, continuous sine-wave power output to your appliances just as they require it.

Adaptive
Performance
Automatic Temperature Compensation (ATC)
Brainy Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Brainy Plus senses the temperature around it and then makes intelligent adjustments.

Adaptive
Performance
For example, in summers or hotter regions, the temperature is high,
and hence the battery is charged to a lower voltage for the same power
back-up performance. This saves you some extra bucks while also
making sure the battery doesn't overheat, lose water, or get damaged.
Similarly, in winters or colder places, the temperature is lower and hence
the battery is charged to a higher boost voltage to make sure you get
the required or expected amount of power back-up.
This makes Brainy Plus a perfect choice for any climate, from the extremes
of Northern America and Europe to the beating heat in Middle-East and
South-East Asia, we are ready for a rough world.

Safe
Charging
Six Stage Charging
Most inverters charge the battery in a flat, linear manner. But just like
monotony upsets you, monotonous or flat charging deteriorates battery
health.
Ideally, 80% of a battery should be fast-charged, while the rest 20% should
be charged slowly to avoid over-heating and loss of water-topping. With
its Generation Four microprocessor, Brainy Plus carries out charging
in six thoughtful stages for maximum efficiency in charging.

Backup
Selection
Battery Selection Switch
Every battery is built to accept a certain maximum allowed charging
speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed
Maintenance Free (SMF) battery requires 6-8 hours, while a Lithium-Ion
battery requires 2-4 hours to get fully charged in a healthy way.
Charging the batteries faster than these healthy limits reduces the battery's
life, and increases maintenance costs and hassles. That's why Brainy Plus is
built with the Right Charger that charges batteries at optimum speed.

Battery Selection Switch is an innovative feature of Brainy Plus that enables you to select the battery type you have installed so that it can control and optimize the charging speed to keep your battery healthy. This makes Brainy Plus compatible with diverse battery sizes as per user need for load and backup time
Beware, If a battery is charged faster than its maximum allowed speed, the battery will frequently get overheated, lose water, and will eventually die off prematurely.
Low
Requisite
Charges in Low Voltages
Typically, batteries require a 130V input to charge itself, but this is not
available across the world at every time. Regions with frequent outages and
low grid voltages may result in poor or no charging.
In such cases, people resort to using stabilizers to get optimum voltage for
charging. To ease this, Brainy Plus is equipped with Advanced Circuitry
that charges the battery with as low as a 90V input.

Discharging Mechanism:
Letting out energy to your appliances elegantly is a breeze for Brainy Plus. We focus on keeping both your appliances & the battery fine.

Power
Reserve
Safe Discharge
With prolonged usage, a battery's life gets reduced. This is what happens to
every battery after multiple charge-discharge cycles, even inverter batteries.
Nerds call it battery fatigue.
Brainy Plus knows how to beat this problem too. When the battery is being
used to power your home and is about to get empty (but not fully empty),
Brainy Plus places a reserve. This means it doesn't let the battery get fully
or deeply discharged, hence extending the life of the battery by leaps
and bounds.
This is similar to the reserve tank we have in our cars and scooters. It makes
sure that even after you run out of battery power, you are still left with the
reserved capacity to get done with emergency situations, by simply pressing
a button.

Soft
Start
Gentle to your appliances
A great beginning makes way for a great journey. Brainy Plus knows this
very well. Unlike traditional inverters that allow a sudden inrush of current
which can be harmful to your appliances, Brainy Plus goes for a cushioned
start-up.
It gradually increases the voltage to let your appliances ease-in. This
prevents electrical and mechanical shocks to the sensitive and costly
appliances in your house.

Generator
compatible
Generator compatibility
Many a times when the local grid fails, you need to depend on your Domestic Power Generators. Ordinary inverters are incompatible with such AC generators due to their high fluctuations. But Brainy Plus can normalise and adapt to such fluctuations, making it perfect to pair up with Domestic Generators.

Regulated
Mains
When power-supply is available.
Smart
AVR
Automatic Voltage Regulation
Frequent voltage and frequency fluctuations in households are a common
occurrence. The moment voltage supply goes down below a certain level,
we observe the speed of fans going slow, the blub light dimming, or the
tube light blinking frequently. This is called a Low Voltage supply.
Also, there are occasions when the voltage jumps high. We all may have
observed that as we switch the bulb on, it goes off and gets fused as it
cannot withstand High Voltage spike.

With Smart Automatic Voltage Regulation (AVR), as and when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Brainy Plus seamlessly switches to the battery power, ensuring safe power supply to all your home appliances.
Overload
Capacity
Brain with a Muscle
Suppose there is a sudden high voltage spike. Now your home's MCB might not be able to protect your appliances, but your Brainy Plus will. It will rapidly switch from mains to the battery. In fact, Brainy Plus can take up to 2.5x its load capacity, supporting your entire home during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.

Advanced
Protection
Protection at it's best
Short circuits are very common. Therefore every household is equipped
with an MCB or main fuse. However, these can be slow and inefficient at
protecting your appliances from damage.
We know how much you love your appliances. Therefore, we have designed
Brainy Plus to add a smart layer of protection to them. It has an inbuilt
Special Resettable Fuse (SRF), which trips and protects all your home
appliances even before the traditional MCB can respond.

Rapid
Switch
Intelligently changing between mains and backup.
Snap
Switch
Switches before you can blink.
Traditional inverters need to be manually switched on when required. This
means your appliances would go off until you get up, do the hard work,
and start your inverter.
But Brainy Plus is blazingly fast. It automatically detects a power-cut or
voltage fluctuation and switches to its power backup mode in milliseconds.
So you and your appliances won't even get to know there was a power-cut.
This means your computer, wifi, and more can run uninterrupted.
Because who likes to stop?

Automatic
Bypass
Switch to hassle-free. Literally.
Now, what if your Home UPS has a technical error, and is unable to switch
your home load back to the main supply? And imagine this happens in
the middle of a summer night, and an electrician can only come the next
morning. Intolerable, right?
This is common with almost every UPS or inverter. But not the Falcon
Plus. With just the push of a button, you can restore power through
your main supply. Yes, it's that simple.



So now you know why we say Brainy Plus is the smartest thing we've ever made. Well, it's just because
when we set out to make a product, we don't aim for beating our competition, we instead aim to push
humanity forward.
Made with Love, at Su-Vastika Solar
Technical Specification
BRAINY + 4000 (Solar Home UPS)
RATING (BULB LOAD in Watt) | : | 3200 WATT ± 2% |
BATTERY VOLTAGE | : | 48V DC |
NO OF BATTERIES (12V RATING) | : | 4 |
INPUT VOLTAGE (AC) / FREQUENCY (HZ) | : | 220VAC;13.2A;50HZ;1P |
OUTPUT VOLTAGE (AC) / FREQUENCY (HZ) | : | 220VAC;11.36A;50HZ;1P |
TECHNOLOGY | : | LATEST BI-DIERECTIONAL TECHNOLOGY BASED DSP PURE SINE WAVE |
MAINS A.C LOW CUT | 180 ± 10 V |
MAINS A.C LOW CUT RECOVERY | 190 ± 10 V |
MAINS A.C HIGH CUT | 265 ± 10 V |
MAINS A.C HIGH CUT RECOVERY | 260 ± 10 V |
MAINS A.C LOW CUT | 85 ± 10 V |
MAINS A.C LOW CUT RECOVERY | 95 ± 10 V |
MAINS A.C HIGH CUT | 290 ± 10 V |
MAINS A.C HIGH CUT RECOVERY | 275 ± 10 V |
MAINS TO BACKUP MODE | ≥ 8ms |
MAINS TO BACKUP MODE | ≥ 20ms |
OUTPUT WAVEFORM | PURE SINE WAVE |
OUTPUT VOLTAGE RANGE | 170V-230VAC |
OUTPUT FREQUENCY | 50.0 ± 0.1 Hz |
CREST FACTOR | 3:1 |
TOTAL HARMONIC DISTORTION | < 5% |
PEAK EFFICIENCY | 85%+/-5% |
FREQUENCY | 50 Hz ± 0.1 Hz |
(Hz) BYPASS FREQUENCY RANGE | 50 Hz ± 0.1 Hz (SAME AS INPUT) |
= > 42V ± 0.2V (DEPENDING ON LOAD) |
= > 43.2.8V ± 0.2V (DEPENDING ON LOAD) |
= > 44V ± 0.2V (DEPENDING ON LOAD) |
= > 44.8V ± 0.2V (DEPENDING ON LOAD) |
= > 44.96V ± 0.2V (DEPENDING ON LOAD) |
58A ± 3A ( DC CURRENT) (IT CAN TAKE UPTO APPROX. 30 SEC TO SHOW OVERLOAD INDICATION DEPENDING ON LOAD & BATTERY STATUS). |
BATTERY TYPE |
PWM CONTROLLED MOSFET BASED CHARGING |
THROUGH DIP SWITCH AT BACK PANEL |
BOOST VOLTAGE UPS SETTING |
FLOAT VOLTAGE UPS |
TEMPERATURE COMPENSATION (ATC) |
85V - 290V ±10V | |
15A ± 1A Factory default, | |
5A to 20A (Front Switch Setable) | |
57.6V Factory default , 56.6VDC to 58.0 VDS (Front Switch Setable) | |
55 ± 1V FLOAT MODE | |
18mV± 5mV/C/12V BATTERY FOR ABSORPTION STAGE 9.0 mV± 5mV/C/12V BATTERY FOR ABSORPTION STAGE |
BACK-UP MODE
ALERT & WARNINGS
STORAGE TEMPERATURE | 0 TO + 40 C |
OPERATING TEMPERATURE | 0 TO + 40 C |
HUMIOPERATING TEMPERATUREDITY | 0-95% NON-CONDENSNG |
ACOUSTIC NOISE (at 1 mts ) | < 45dB from 1 METER |
PROTECTION GLASS | IP-20 |
DIMENSIONS (WXDXH) UPS | 610 X 400X 540 (mm) |
NET WEIGHT | 36.700 KG |
GROSS WEIGHT (WITH PACKAGING) | 37.300 KG |
GROSS WEIGHT WITH MASTER CARTON | 38.900 KG |
INPUT TERMINAL BLOCK (NEL) | TB 30 AMP |
OUTPUT TERMINAL BLOCK (NEL) | TB 30 AMP |
SOLAR INPUT TERMINAL BLOCK | TB 80 AMP |
BATTERY WIRE | 16 Sq mm |
MINIMUM BATTERY CAPACITY | 42 AH - 200 AH |
INPUT/OUTPUT PLUG | 20A ISI MARKED |
MCB (LOAD AT MAINS BYPASS MODE) | 25A (5500 WATT ± 10%) Maximum limit |
DC FUSE RATING (FOR REVERSE POLAIRTY PROTECTION) | 40AMP DC 2POLE |