What is a Home UPS?
Inverter

High Energy Storage
(sufficient for homes)
Slow switchingUPS

Low Energy Storage
(sufficient for Pcs)
Fast switchingHome UPS
the best of both worlds
The Home UPS has high energy capacity, enough to support your
home in a power failure, and switches between the main power supply
and battery power in just milliseconds.
Now that is seriously fast.
What does a Home UPS do?
During power-supply
Stabilizes the power-supply to keep your appliances healthy.
During power-cut
Smartly switches to battery
power and
provides a regulated
power supply
for your home.


a Home UPS. With a brain.
Powered with Artificial Intelligence.
works in three modes:

Regulated
Mains
When power-supply is available.
Smart
AVR
Automatic Voltage Regulation
Frequent voltage and frequency fluctuations in households are a common occurrence. The moment voltage supply goes down below a certain level, we observe the speed of fans going slow, the blub light dimming, or the tube light blinking frequently. This is called a Low Voltage supply. Also, there are occasions when the voltage jumps high. We all may have observed that as we switch the bulb on, it goes off and gets fused as it cannot withstand High Voltage spike.

With Smart Automatic Voltage Regulation (AVR), as and when your mains supply voltage fluctuates (rises or drops beyond the Safe Voltage range), Falcon Plus seamlessly switches to the battery power, ensuring safe power supply to all your home appliances.
Overload
Capacity
Brain with a Muscle
Suppose there is a sudden high voltage spike. Now your home's MCB might not be able to protect your appliances, but your Falcon Plus will. It will rapidly switch from mains to the battery. In fact, Falcon Plus can take up to 2.5x its load capacity, supporting your entire home during that high voltage spike. It then intelligently reminds you to turn off the extra appliances, so that the load can be reduced.

Advanced
Protection
Protection at it's best
Short circuits are very common. Therefore every household is equipped
with an MCB or main fuse. However, these can be slow and inefficient at
protecting your appliances from damage.
We know how much you love your appliances. Therefore, we have designed
Falcon Plus to add a smart layer of protection to them. It has an inbuilt
Special Resettable Fuse (SRF), which trips and protects all your home
appliances even before the traditional MCB can respond.

Rapid
Switch
Intelligently changing between mains and backup.
Snap
Switch
Switches before you can blink.
Traditional inverters need to be manually switched on when required. This
means your appliances would go off until you get up, do the hard work,
and start your inverter.
But Falcon Plus is blazingly fast. It automatically detects a power-cut or
voltage fluctuation and switches to its power backup mode in milliseconds.
So you and your appliances won't even get to know there was a power-cut.
This means your computer, wifi, and more can run uninterrupted.
Because who likes to stop?

Automatic
Bypass
Switch to hassle-free. Literally.
Now, what if your Home UPS has a technical error, and is unable to switch
your home load back to the main supply? And imagine this happens in
the middle of a summer night, and an electrician can only come the next
morning. Intolerable, right?
This is common with almost every UPS or inverter. But not the Falcon
Plus. With just the push of a button, you can restore power through
your main supply.

Inverter
Mode
Charging and backup cycles.
The battery sits at the heart of your inverter's power back-up
functionality. Charging and Dis-charging cycles define life of a
battery, and making both these processes efficient is crucial.
Falcon Plus is built to keep your battery healthy. It is designed
for efficient charging and discharging, hence keeping the battery
running for longer with reduced upkeep efforts and costs.

Choice of battery: depends upon Load & Back up time
Example 1-2 BHK, 250W loadLow back-up (15 min)
Sealed Maintenance Free60Ah
Medium back-up (1 Hr)
Tubular/LA75Ah to 100Ah
High back-up (3 - 4 Hr)
Tubular/LA150Ah
Battery Charging Mechanism:
Falcon Plus is built with a Right Charging Mechanism that
charges batteries optimally for longer life

Pure
Wave
Pure Sine Wave Technology
Many inverters still provide a square wave output which is not healthy for your appliances. Falcon Plus is designed to provide a smooth, continuous sine-wave power output to your appliances just as they require it.

Adaptive
Performance
Automatic Temperature Compensation (ATC)
Falcon Plus is designed for rough weather conditions. It has an ambient sensor and antenna placed right upon it. With advanced Automatic Temperature Compensation (ATC) built right into the microprocessor, Falcon Plus senses the temperature around it and then makes intelligent adjustments.

Adaptive
Performance
For example, in summers or hotter regions, the temperature is high,
and hence the battery is charged to a lower voltage for the same power
back-up performance. This saves you some extra bucks while also
making sure the battery doesn't overheat, lose water, or get damaged.
Similarly, in winters or colder places, the temperature is lower and hence
the battery is charged to a higher boost voltage to make sure you get
the required or expected amount of power back-up.
This makes Falcon Plus a perfect choice for any climate, from the extremes
of Northern America and Europe to the beating heat in Middle-East and
South-East Asia, we are ready for a rough world.

Safe
Charging
Six Stage Charging
Most inverters charge the battery in a flat, linear manner. But just like
monotony upsets you, monotonous or flat charging deteriorates battery
health.
Ideally, 80% of a battery should be fast-charged, while the rest 20% should
be charged slowly to avoid over-heating and loss of water-topping. With
its Generation Four microprocessor, Falcon Plus carries out charging
in six thoughtful stages for maximum efficiency in charging.

Backup
Selection
Battery Selection Switch
Every battery is built to accept a certain maximum allowed charging
speed. A Tubular Lead-Acid battery needs a minimum of 10 hours, a Sealed
Maintenance Free (SMF) battery requires 6-8 hours, while a Lithium-Ion
battery requires 2-4 hours to get fully charged in a healthy way.
Charging the batteries faster than these healthy limits reduces the battery's
life, and increases maintenance costs and hassles. That's why Falcon Plus is
built with the Right Charger that charges batteries at optimum speed.

Battery Selection Switch is an innovative feature of Falcon Plus that enables you to select the battery type you have installed so that it can control and optimize the charging speed to keep your battery healthy. This makes Falcon Plus compatible with diverse battery sizes as per user need for load and backup time
Beware, If a battery is charged faster than its maximum allowed speed, the battery will frequently get overheated, lose water, and will eventually die off prematurely.
Low
Requisite
Charges in Low Voltages
Typically, batteries require a 130V input to charge itself, but this is not
available across the world at every time. Regions with frequent outages and
low grid voltages may result in poor or no charging.
In such cases, people resort to using stabilizers to get optimum voltage for
charging. To ease this, Falcon Plus is equipped with Advanced Circuitry
that charges the battery with as low as a 90V input.

Discharging Mechanism:
Letting out energy to your appliances elegantly is a breeze for Falcon Plus. We focus on keeping both your appliances & the battery fine.

Power
Reserve
Safe Discharge
With prolonged usage, a battery's life gets reduced. This is what happens to
every battery after multiple charge-discharge cycles, even inverter batteries.
Nerds call it battery fatigue.
Falcon Plus knows how to beat this problem too. When the battery is being
used to power your home and is about to get empty (but not fully empty),
Falcon Plus places a reserve. This means it doesn't let the battery get fully
or deeply discharged, hence extending the life of the battery by leaps
and bounds.
This is similar to the reserve tank we have in our cars and scooters. It makes
sure that even after you run out of battery power, you are still left with the
reserved capacity to get done with emergency situations, by simply pressing
a button.

Soft
Start
Gentle to your appliances
A great beginning makes way for a great journey. Falcon Plus knows this
very well. Unlike traditional inverters that allow a sudden inrush of current
which can be harmful to your appliances, Falcon Plus goes for a cushioned
start-up.
It gradually increases the voltage to let your appliances ease-in. This
prevents electrical and mechanical shocks to the sensitive and costly
appliances in your house.

Generator
compatible
Generator compatibility
Many a times when the local grid fails, you need to depend on your Domestic Power Generators. Ordinary inverters are incompatible with such AC generators due to their high fluctuations. But Falcon Plus can normalise and adapt to such fluctuations, making it perfect to pair up with Domestic Generators.



So now you know why we say Falcon Plus is the smartest thing we've ever made. Well, it's just because
when we set out to make a product, we don't aim for beating our competition, we instead aim to push
humanity forward.
Made with Love, at Su-Vastika Solar
Technical Specification
FALCON+ 1100 (Home UPS)
RATING (BULB LOAD in Watt) | : | 760 WATT ± 2% |
BATTERY VOLTAGE | : | 12V DC |
NO OF BATTERIES (12V RATING) | : | 1 |
INPUT VOLTAGE (AC) / FREQUENCY (HZ) | : | 220VAC;13.2A;50HZ;1P |
OUTPUT VOLTAGE (AC) / FREQUENCY (HZ) | : | 220VAC;11.36A;50HZ;1P |
TECHNOLOGY | : | LATEST BI-DIERECTIONAL TECHNOLOGY BASED DSP PURE SINE WAVE |
MAINS A.C LOW CUT | 180 ± 10 V |
MAINS A.C LOW CUT RECOVERY | 190 ± 10 V |
MAINS A.C HIGH CUT | 265 ± 10 V |
MAINS A.C HIGH CUT RECOVERY | 260 ± 10 V |
MAINS A.C LOW CUT | 85 ± 10 V |
MAINS A.C LOW CUT RECOVERY | 95 ± 10 V |
MAINS A.C HIGH CUT | 290 ± 10 V |
MAINS A.C HIGH CUT RECOVERY | 275 ± 10 V |
MAINS TO BACKUP MODE | ≥ 8ms |
MAINS TO BACKUP MODE | ≥ 20ms |
OUTPUT WAVEFORM | PURE SINE WAVE |
OUTPUT VOLTAGE RANGE | 195V-230VAC |
OUTPUT FREQUENCY | 50.0 ± 0.1 Hz |
CREST FACTOR | 3:1 |
TOTAL HARMONIC DISTORTION | < 5% |
PEAK EFFICIENCY | 85% + 5% |
FREQUENCY | 50 Hz ± 0.1 Hz |
(Hz) BYPASS FREQUENCY RANGE | 21.0V ± 0.4V (DEPENDING ON LOAD) |
= > 10.5V ± 0.2V (DEPENDING ON LOAD) |
= > 10.8V ± 0.2V (DEPENDING ON LOAD) |
= > 11V ± 0.2V (DEPENDING ON LOAD) |
= > 11.2V ± 0.2V (DEPENDING ON LOAD) |
= > 11.4V ± 0.2V (DEPENDING ON LOAD) |
65A ± 2A ( DC CURRENT) (IT CAN TAKE UPTO APPROX. 30 SEC TO SHOW OVERLOAD INDICATION DEPENDING ON LOAD & BATTERY STATUS). |
BATTERY TYPE |
PWM CONTROLLED MOSFET BASED CHARGING |
THROUGH DIP SWITCH AT BACK PANEL |
BOOST VOLTAGE UPS SETTING |
FLOAT VOLTAGE UPS |
TEMPERATURE COMPENSATION (ATC) |
85V - 290V ±10V | |
25A ± 0.5A / 15A ± 0.5A / | |
10A ± 0.5A / 5A ± 0.5A | |
14.0v/14.4v + TEMP. COMPENSATION ± 0.2V : LA/TUBULAR-SMF | |
13.6 + TEMPERATURE COMPENSATION ± 0.2V | |
18mV± 5mV/C/12V BATTERY FOR ABSORPTION STAGE | |
9.0 mV± 5mV/C/12V BATTERY FOR ABSORPTION STAGE |
BACK-UP MODE
ALERT & WARNINGS
STORAGE TEMPERATURE | 0 TO + 40 C |
OPERATING TEMPERATURE | 0 TO + 40 C |
HUMIOPERATING TEMPERATUREDITY | 0-95% NON-CONDENSNG |
ACOUSTIC NOISE (at 1 mts ) | < 45dB from 1 METER |
PROTECTION GLASS | IP-20 |
DIMENSIONS (WXDXH) UPS | 275 X 270 X 121 (mm) |
NET WEIGHT | 9.36 KG |
GROSS WEIGHT (WITH PACKAGING) | 9.83 KG |
GROSS WEIGHT WITH MASTER CARTON | 10.2 KG |
INPUT WIRE SIZE in Sq mm | 1 Sq mm 10/13A |
OUTPUT SOCKET (INDIA - ROUND / EXPORT - UNIVERSAL ) | 10/13A |
BATTERY WIRE in Sq mm | 10 Sq mm |
MINIMUM BATTERY CAPACITY | 42 AH - 300 AH |
INPUT/OUTPUT PLUG | 20A ISI MARKED |
MCB (LOAD AT MAINS BYPASS MODE) | 6A (1500 WATT ± 10%) Maximum limit |
DC FUSE RATING (FOR REVERSE POLAIRTY PROTECTION) | 40 A + 40A + 40A |